GENPACS-MTU LINE - GENERATOR FROM 300KVA TO 2,500KVA
GENPACS MTU GM550S
For more detail, please click below (Catalogue Genpacs-MTU Line)
Engine
ENGINE: MTU 10V1600G20F
- Diesel 4-cycle, Direct Injection, Electric starting with 24VDC battery, c/w 24VDC charging alternator.
- Cooling by radiator and self-driven fan
- Easy Replaceable Filters (Oil, Fuel and Air)
4016 61TRG3 for 2025-2500KVA GENPACS |
ENGINE DATA | |
|
MTU – MADE IN GERMANY |
|
10V1600G20F |
|
10V |
|
17.5 |
|
122x150 |
|
1500 |
|
493 |
|
Auto Electronic ECU8 |
|
Turbo Charged |
|
+/- 0.25% |
|
107 |
|
85 |
|
800 |
Lubricant Capacity (l) | 60.5 |
Alternators
ALTERNATOR: MECC ALTE ECO 40-3S/4, LEROYSOMER LSA47.2M7, SINCRO SK355MS
- Synchronous, Brushless, IP23, Insulation Class H.
- Self auto Excited, Voltage Control by AVR with variation at 0.25 to 0.5%.
MECC ALTE ECO 40-3S/4 | LEROYSOMER LSA47.2M7 | SINCRO SK355MS |
ALTERNATOR DATA | |
|
MECC ALTE-LEROYSOMER-SINCRO |
|
ECO 40-3S/4-LSA47.2M7-SK355MS |
|
50Hz/ 1500RPM |
|
380/220, 400/230 |
|
500/550 |
|
3 |
|
0.8 |
|
4 |
|
H |
|
IP23 |
|
MECC ALTE: 0.25%, LEROYSOMER: 0.5%, SINCRO:0.25% |
Controller
CONTROLLER GENPACS-7320MKII – MADE IN GERMANY
FEATURES:
- Controlling Generator, Auto Mains Failure (AMF) and Ready to connect to any ATS
- Remote Control Available
- Recording Fault, Starts
- Emergency Stop Button on Control Panel
- Generator Metering by LCD: 3-phase Voltage, 3-phase Current, Frequency, Rotation, Oil Pressure, Water Temperature, Battery Voltage, Run-hour, Total Kw, Total Kwh, Power Factor.
- Mains Metering: Frequency, Voltage.
ALARM AND PROTECTION:
- Alarm and Shut-down: High Water Temperature, Low Oil Pressure, Over or Under Frequency/ Rotation, Over/Under AC Voltage, Over Current, Exceed Power, Short Circuit, Emergency Stop Button Pressed, Over Cranking.
- Alarm: Charging Failure, Over/Under Battery Voltage.
Standard Accessories
- Heavy duty Base Frame with Anti-Vibration Rubbers.
- Fuel day tank on Base Frame
- Exhaust silencers
- Battery
- MCCB (ACB on request)
- Technical Documents.
Advantaged Features
ADVANTAGED FEATURES
|
Notes
- Output Power is in accordance with ISO8528 at temperature up to 45ºC, humidity up to 95%.
- Standby Power is maximum power available for the duration of any power outage at variable load. No overload is allowed.
- Prime Power is available for continuous operation at variable load. The average output power during 24h period of operation must not exceed 80% of the Prime Power. 5% over load is allowed in 1h with every 12h of operation.