GENPACS-CUMMINS LINE - GENERATOR FROM 500KVA TO 2045KVA

Description

Genpacs cummins Line 2020

GENERAL

ENGINE: CUMMINS MADE IN USA or UK

  • Diesel 4-cycle, Direct Injection, Electric governor, Fuel Pump, Electric Start c/w battery charging alternator.
  • Aspiration: Turbo Charged.
  • Steady state speed stability at any constant load is 0.25% or better.
  • Water Cooling by tropical radiator and self-driven fan.
  • Easy Replaceable Filters (Oil, Fuel and Air).
  • Fuel type: Standard Diesel Oil.

ALTERNATOR: LEROYSOMER (EU) or STAMFORD (UK)

  • Synchronous, Brushless, IP23, Insulation Class H, 4P, 1500 RPM-50Hz.
  • Standard Temperature Rise is 125 ºC, Temperature Rise up to 163 ºC.
  • Standard AC Voltage: 380V/220V, 400V/230V.
  • Operation Environment: tropical condition with altitude < 1000m.
  • Colling type: By direct fan.
  • Excitation system: AREP, PMG, AREP + PMI.
  • Self auto Excited.
  • Voltage Control by AVR with variation at max. ± 0.5%.
  • TIF < 50, Wave Form IEC THF < 2%.
  • Total Harmonic distortion THD (**) < 4 %.
  • Over Speed 2250 RPM within 2 minutes.
  • Short Circuit 300% within 10s.
  • Manufacture Standard: BS5000, VDE0530, VDE 0975, IEC34, EN 61000-6-3, EN 61000-6-2, EN 55011 Group 1 class B standard for European Zone (CE marking), ISO 9001, ISO 14001, IEC 60034, NEMA MG 1.32-33, ISO 8528-3, CSA C22.2 n°100, AS1359, UL 1446 (UL 1004 on request).
LSA 47.2
LINE LSA 47.2: 365-600KVA ( Detail)
LSA49.3
 LINE LSA49.3: 660-1000KVA ( Detail)
LSA 50.2
LINE LSA50.2: 1040-1640KVA ( Detail)
lsa 52.3
LINE LSA52.3: 1860-2500KVA ( Detail)

CONTROL PANEL: GENPACS-7320MKII – CE MARK- POWERED BY DSE 7320MKII

Features:

  • Controlling Generator, Auto Mains Failure (AMF) and ready to connect to any ATS.
  • Remote Control Available.
  • Standard connection by RS232 and RS485 port.
  • BMS connection support.
  • Synchronizing Connection Available.
  • Voltage adjuster.
  • Speed adjuster.
  • Fuel level monitoring and low level alarm.
  • Load coming/cut off indication.
  • Indication and Metering by LCD and LED.
  • Recording Fault, Starts.
  • Fuel Pump Control.
  • Emergency Stop Button on Control Panel and on Soundproof.
  • Generator Metering: 3-phase Voltage, 3-phase Current, Frequency, Rotation, Oil Pressure, Water Temperature, Battery Voltage, DC voltage, Run-hour, KW, KWh, KVA, KVAh, KVAr, KVARh, Power Factor, fuel level.
  • Mains Metering: Frequency, Voltage.
DSE 7320

Alarm and Protection:

  • Alarm and Shut-down: High Water Temperature, Low Oil Pressure, Over or Under Frequency/ Rotation, Over/Under AC Voltage, Over Current, Exceed Power, Short Circuit, Emergency Stop Button Pressed, Over Cranking.
  • Alarm: Charging Failure, Over/Under Battery Voltage.

Standard Accessories:

  • Heavy duty Base Frame with Anti-Vibration Rubbers.
  • Heavy Duty Batteries and AC Charger Available.
  • Fuel Day Tank on Base Frame up to 500KVA Prime Power.
  • ABB/Merlin Gerin output MCCB up to 800A for 500KVA Prime Power.
  • Technical Documents.

Other Options:

  • Merlin Gerin/ABB output ACB, Genpacs Auto Transfer Switch 800A to 3200A equipped by ACB.
  • Genpacs Auto Synchronizing Panel for max 12 generators up to 2,250 KVA per set.
  • Wireless remote control feature by 3-4G network.
  • Genpacs Sound Proof: Below 70 Db (A) at 7m distance.

GENPACS - CUMMINS LINE: TECHNICAL SPECIFICATION

CUMMINS TECHNICAL SPECIFICATION

ADVANTAGED FEATURES:

  • The quality of GENPACS-CUMMINS line generator is guaranteed as the highest EU standard.
  • Generator is tropicalized for operation on tropical conditions.
  • Generator is available tested at full load before delivery under ISO8528 and DIN6271.
  • Independent Test and Inspection are available on request.
  • Quality Product is controlled by ISO 9001:2015.

NOTES:

  • Generator is manufacture in accordance with ISO8528, ISO3046, AS2789, DIN6271, BS5514, NEMA MG1 -22.34, NEMA
    MG1 -32, BS4999 part 40, BS5000, VDE0975 class G&N, VDE0530 at temperature up to 45ºC with average equal up to 35ºC, maximum altitude up to 1000m from sea level, humidity up to 100%, average equal up to 85%.
  • Standby Power is maximum power available for the duration of any power outage at variable load. No overload is allowed.
  • Prime Power is available for continuous operation at variable load. The average output power during 24h period of operation must not exceed 80% of the Prime Power. 10% over load is allowed in 1h with every 12h of operation.