GENPACS-CUMMINS LINE - GENERATOR FROM 500KVA TO 2045KVA
Description
GENERAL
ENGINE: CUMMINS MADE IN USA or UK
- Diesel 4-cycle, Direct Injection, Electric governor, Fuel Pump, Electric Start c/w battery charging alternator.
- Aspiration: Turbo Charged.
- Steady state speed stability at any constant load is 0.25% or better.
- Water Cooling by tropical radiator and self-driven fan.
- Easy Replaceable Filters (Oil, Fuel and Air).
- Fuel type: Standard Diesel Oil.
ALTERNATOR: LEROYSOMER (EU) or STAMFORD (UK)
- Synchronous, Brushless, IP23, Insulation Class H, 4P, 1500 RPM-50Hz.
- Standard Temperature Rise is 125 ºC, Temperature Rise up to 163 ºC.
- Standard AC Voltage: 380V/220V, 400V/230V.
- Operation Environment: tropical condition with altitude < 1000m.
- Colling type: By direct fan.
- Excitation system: AREP, PMG, AREP + PMI.
- Self auto Excited.
- Voltage Control by AVR with variation at max. ± 0.5%.
- TIF < 50, Wave Form IEC THF < 2%.
- Total Harmonic distortion THD (**) < 4 %.
- Over Speed 2250 RPM within 2 minutes.
- Short Circuit 300% within 10s.
- Manufacture Standard: BS5000, VDE0530, VDE 0975, IEC34, EN 61000-6-3, EN 61000-6-2, EN 55011 Group 1 class B standard for European Zone (CE marking), ISO 9001, ISO 14001, IEC 60034, NEMA MG 1.32-33, ISO 8528-3, CSA C22.2 n°100, AS1359, UL 1446 (UL 1004 on request).
CONTROL PANEL: GENPACS-7320MKII – CE MARK- POWERED BY DSE 7320MKII
Features:
- Controlling Generator, Auto Mains Failure (AMF) and ready to connect to any ATS.
- Remote Control Available.
- Standard connection by RS232 and RS485 port.
- BMS connection support.
- Synchronizing Connection Available.
- Voltage adjuster.
- Speed adjuster.
- Fuel level monitoring and low level alarm.
- Load coming/cut off indication.
- Indication and Metering by LCD and LED.
- Recording Fault, Starts.
- Fuel Pump Control.
- Emergency Stop Button on Control Panel and on Soundproof.
- Generator Metering: 3-phase Voltage, 3-phase Current, Frequency, Rotation, Oil Pressure, Water Temperature, Battery Voltage, DC voltage, Run-hour, KW, KWh, KVA, KVAh, KVAr, KVARh, Power Factor, fuel level.
- Mains Metering: Frequency, Voltage.
![DSE 7320](/images/Genpacs/product/control/DSE-7320.jpg)
Alarm and Protection:
- Alarm and Shut-down: High Water Temperature, Low Oil Pressure, Over or Under Frequency/ Rotation, Over/Under AC Voltage, Over Current, Exceed Power, Short Circuit, Emergency Stop Button Pressed, Over Cranking.
- Alarm: Charging Failure, Over/Under Battery Voltage.
Standard Accessories:
- Heavy duty Base Frame with Anti-Vibration Rubbers.
- Heavy Duty Batteries and AC Charger Available.
- Fuel Day Tank on Base Frame up to 500KVA Prime Power.
- ABB/Merlin Gerin output MCCB up to 800A for 500KVA Prime Power.
- Technical Documents.
Other Options:
- Merlin Gerin/ABB output ACB, Genpacs Auto Transfer Switch 800A to 3200A equipped by ACB.
- Genpacs Auto Synchronizing Panel for max 12 generators up to 2,250 KVA per set.
- Wireless remote control feature by 3-4G network.
- Genpacs Sound Proof: Below 70 Db (A) at 7m distance.
GENPACS - CUMMINS LINE: TECHNICAL SPECIFICATION
ADVANTAGED FEATURES:
- The quality of GENPACS-CUMMINS line generator is guaranteed as the highest EU standard.
- Generator is tropicalized for operation on tropical conditions.
- Generator is available tested at full load before delivery under ISO8528 and DIN6271.
- Independent Test and Inspection are available on request.
- Quality Product is controlled by ISO 9001:2015.
NOTES:
- Generator is manufacture in accordance with ISO8528, ISO3046, AS2789, DIN6271, BS5514, NEMA MG1 -22.34, NEMA
MG1 -32, BS4999 part 40, BS5000, VDE0975 class G&N, VDE0530 at temperature up to 45ºC with average equal up to 35ºC, maximum altitude up to 1000m from sea level, humidity up to 100%, average equal up to 85%. - Standby Power is maximum power available for the duration of any power outage at variable load. No overload is allowed.
- Prime Power is available for continuous operation at variable load. The average output power during 24h period of operation must not exceed 80% of the Prime Power. 10% over load is allowed in 1h with every 12h of operation.